Medical Radiation Protective Lead Vests Used in Dental CT Rooms

Product Details
Customization: Available
Customized: Non-Customized
Certification: ISO
Still deciding? Get samples of US$ 800/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
  • Medical Radiation Protective Lead Vests Used in Dental CT Rooms
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Application
  • Customer Feedback
Overview

Basic Info.

Gender
Female, Male
Suitable for
Elderly, Children, Adult
Material
Lead, Lead
Type
X-ray Shield, Lead Cloth
Application
Aviation, Electronics, Industrial, Medical, Chemical, Industrial, Medical, Chemical, Hospital
Standard
GB, GB
Purity
>99.99%
Shape
Oval
Alloy
Non-Alloy
Feature
Reusable
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Logo Printing
Without Logo Printing
Group
Male/Female
Product Name
Anti Radiation Lead Cloth
Price Term
Fob CIF CFR EXW Fca
Payment Term
30% Advance+70% Balance
Delivery Time
3-5days
Transport Package
Standard Packing
Trademark
RENAI STEEL
Origin
China

Product Description

Product Description

X ray radiation protection  Lead clothes

1. The consumer can choose different protective apron according to his requirement.

2. The protective apron is mainly used for the radiation operator to prevent the scattering of the X-ray and keep his body healthy during the operation.
 
3. Before operation, the operator should check the inner and outer surface packing cloth of the protective apron wheather it is firm or not, check wheather the connection of the fittings is firm, check whether the attenuation equivalent on the mark is suitable to the operator.

 

Medical Radiation Protective Lead Vests Used in Dental CT Rooms
Medical Radiation Protective Lead Vests Used in Dental CT Rooms

4. After the examination, put on the protective apron, then operate.
5. After the operation, lie the protective apron flat or hang it up by coat hanger to avoid breach caused by a long-time fold and avoid radial leak.
 
6. When storing the protective apron, put it in the well airy room where untouched the sun shine and far away from the heat source. Must not touch with the acid or alkali chemical products to ensure the service life of it.
 
7. According to the standard of GB16757-1997, the service life of the protective apron is 4~5 years. The user should have a regular examination to it once a year. The examination method is to fondle or bend the clothing by hand and check it by eyes. If the crackle of the product exceeds one third of it, the product cannot be used any more, must be discarded or renewed.
 
8. The attenuation equivalent of the protective products is: 0.25mmPb, 0.35mmPb, 0.5mmPb

 The voltage of the X-ray radiation tube is: 100kv
 

Medical Radiation Protective Lead Vests Used in Dental CT Rooms
Medical Radiation Protective Lead Vests Used in Dental CT Rooms

 

 

 

Company Profile

Shandong Renai Iron&Steel Co.,Ltd.
Located in Liaocheng city, Shandong province,which is a picturesque city be crowned as "the Oriental Venice". In order to meetcustomer request of product variety,we established long term friendly cooperation with famous domestic mill plants. With goodreputation in Europe, Southeast Asia, Middle East, South America and Africa,our annual export volume twenty-five milliondollars,about forty percentage of total sales,especially our Wear Resistant Steel Plate, Weathering Steel Plate, High Strength Carbon Steel Plate are popular with Southeast Asia, Middle East customer.
Medical Radiation Protective Lead Vests Used in Dental CT Rooms

Application

X-ray lead clothing is generally used for the protection of X-ray and nuclear industry radiation environment, suitable for doctors, patients who need to be exposed to X-ray, laboratory personnel, industrial radiation environment construction and monitoring personnel, etc. The average lead suit is 0.1mmpb-0.5mmpb. The common 0.35mmpb is heavier. A long-sleeved suit is about 4-6kg. The service life of lead protective clothing is generally 5-8 years. It should be noted that it cannot be folded when stored, otherwise it is easy to cause damage to the corner part and affect the protective effect.
Medical Radiation Protective Lead Vests Used in Dental CT Rooms

Customer Feedback

Medical Radiation Protective Lead Vests Used in Dental CT Rooms

Medical Radiation Protective Lead Vests Used in Dental CT Rooms                                                    Contact us: Please contact us for more details.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier